Rated Capacity : 75Ah

Our state-of-the-art battery management system (BMS) integrates advanced intelligence to deliver unparalleled protection against overcharging, overdischarging, overcurrent, and temperature variations. With built-in alarm features and safety measures, our BMS ensures the highest level of safety and security.

Furthermore, our batteries offer a historical data storage capability that enables efficient monitoring and analysis. Our product stands out in delivering backup power supply for communication purposes, specifically designed for unique scenarios and high-rate discharge demands.

The exceptional performance and reliability of our batteries make them ideal for critical environments like data centers and communication centers, where they find extensive application.

Optimize for Power: Performance and Protection

Space-saving installations with hanging poles/walls/towers. Achieve rapid deployment and save 80% on installation time.

Good High Temperature Performance

Ambient temperature <38°C no need for air-conditioning cooling, saving energy.

Intelligent Protection

With voltage, current and temperature intelligent protection function.

5G-Tower-Cellular-Battery
CF4875T-3U
CF4875T-3U

Worry-Free
Long-Life Solutions

Streamlined Operation and Maintenance for Enhanced Efficiency.

Life Span

3000 times @ 0.5C | 80%DOD,25℃

Easy Operation and Maintenance

Integrated BMS design, battery supports self-management SOC, SOH management and other functions

Anti-theft Function

Multiple anti-theft functions can be selected

Module Specification and Parameters (1P15S)

Rated Energy

3600Wh

Rated Capacity

75Ah

Rated Voltage

48V

Voltage Range

42V-52.5V

Charging Current

35A

Discharging Current

75A

Operating Temperature:  Charging:0-50°C;Discharging:-20-55°C;Storage:-30 – 45°C.

Self-Discharging Rate: ≤3% (0-30°C/3 months).

Dimension: 440×370×130mm(W*D*H)

Weight: 30kg

Life Span: 3000 times @ 80% DOD, 0.5C/0.5C

Battery Management System

BMS Introduction

Communication Interface

RS485 / RS232 / CAN

Signal Acquisition Function

It has acquisitions of single voltage and external busbar voltage, battery module total voltage,charging/discharging current,surface temperature of battery cell, BMS board temperature for each series.

Battery Cell Equalization Function

The battery has a passive equalization function. When the cell voltage difference exceeds a certain value during charging, the equalization function will be started.

Charging Current Limit Function

It has the ability to automatically enter current-limiting charging when the battery is detected with low voltage, high voltage, low temperature, high temperature, poor consistency, or charging overcurrent protection.

Voltage Acquisition Accuracy

0-5V,Detection accuracy ≤ 10mV;
0-60V Detection accuracy ≤ 0.5%

Current Acquisition Accuracy

Detection accuracy ≤ 1%  (0.5C Charging / Discharging)

Anti-theft Function

Software anti-theft, communication anti-theft, gyroscope anti-theft and other functions

System Device Failure Alarm

It has failure detection and alarm function for key components of BMS board. While it is detected with temperature sensor failure, voltage detection failures, charge and discharge MOS failure, an alarm will be generated and the charge and discharge loops will be disconnected (if the charge and discharge loop is damaged, it is not required to disconnect), the battery cannot recover automatically, and all the indicators flash to prompt.

Histroical Storage Function

500 historical records, 10000 historical records and life-cycle storage are optional; Independent storage space; BMS has power failure preservation capability; Historical data records include battery voltage, current, ambient temperature, SOC, SOH, cycle times, cumulative discharge capacity and other data.